Agilent provides a large selection of convenient ICP-MS application kits to ensure that everything is available to run the most challenging samples. Application kits for organic solvents, semi-conductor samples, inert applications where HF is used, and speciation kits for environmental applications are all offered.The application kits include the correct components required to run your application, such as torch, spray chamber, nebulizer, peristaltic pump tubing or interfacing supplies. The application kits also provide a lower cost than purchasing the supplies individually.
Application Kits for ICP-MS
Бренд: Agilent Technologies
Категория: Расходные материалы и запасные части
Бренд: Agilent Technologies
Список продуктов
Фото | Артикул | Описание |
---|---|---|
![]() | 5188-6527 | 🔗6020 Interference Check Solution B. For use with ICP-MS systems. Contains: 20 ppm of Cr, Co, Cu, Mn, Ni and V, 10 ppm of As, Cd, Se, and Zn, 5 ppm of Ag. Bottle of 100ml, Matrix = ... |
![]() | 5183-4688 | 🔗Environmental calibration standard, 1000 ppm each of Fe, K, CA, Na, Mg, 10 ppm each of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn, Th, U in 10% HNO3, 100 mL. |
![]() | 5183-4687 | 🔗Environmental Spike Mix |
![]() | G3154-65002 | 🔗Guard Column for arsenic Speciation |
![]() | 5191-4570 | 🔗ICP-MS Internal Std Mix (100mL) |
![]() | G3280-60580 | 🔗ICP-MS organic solvent sample introduction kit, for Agilent 7700, 7800, 7850, 7900, 8800, 8900. |
![]() | 5190-8599 | 🔗ICS interference A for EPA 200.7, 5 mg/mL Al, Ca, Mg, 2 mg/mL Fe, in 20% HCl, 500 mL |
![]() | 5183-4682 | 🔗Initial calibration verification, 1,000 mg/L of Fe, K, Ca, Na, Mg; 100 mg/L of Sr; 10 mg/L of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn, Th, U |
![]() | 5183-4681 | 🔗Internal standard mix 10 μg/mL each of Bi, Ge, In, Sc, Tb, Y and Li (6) in 5% HNO3, 100 mL bottle. Dangerous goods, not available in Japan. |
![]() | 5188-6525 | 🔗Internal standard mix, for ICP-MS systems |
![]() | G4912-68003 | 🔗PFA Inert sample introduction kit with 1.5 mm id platinum injector, for organic samples |
![]() | G4912-68002 | 🔗PFA Inert sample introduction kit with 1.5 mm id sapphire injector, for organic samples |
![]() | G4912-68001 | 🔗PFA Inert sample introduction kit with 2.5 mm id platinum injector, for aqueous samples containing HF |
![]() | G4912-68000 | 🔗PFA Inert sample introduction kit with 2.5 mm id sapphire injector, for aqueous samples containing HF |
![]() | G3154-65001 | 🔗Speciation column for testing arsenic in drinking water by HPLC-ICP-MS |
![]() | G3288-80000 | 🔗Speciation column for testing arsenic in urine, food, etc. by HPLC-ICP-MS |
![]() | G3268-80001 | 🔗Speciation column for testing chromium in drinking water by HPLC-ICP-MS |
![]() | 5188-6526 | 🔗6020 Interference Check Solution A. in 5% HNO3 with trace amounts of HF |