In 2005, Agilent released an improved FPD with minimum detectable levels (MDL) of 3.6 pg/s for sulfur and 60 fg/s for phosphorus. This is more than a 5 times improvement for sulfur. The updated design is based on a one-piece, deactivated transferline jet assembly and improved optics. Upgrade kits are available.
Flame Photometric Detector (FPD) Supplies for GC
Бренд: Agilent Technologies
Категория: Расходные материалы и запасные части
Бренд: Agilent Technologies
Список продуктов
Фото | Артикул | Описание |
---|---|---|
![]() | 19256-60800 | 🔗Igniter replacement kit |
![]() | 1000-1438 | 🔗Lens, glass, convex, 31.2 mm focal length |
![]() | 2190-0584 | 🔗Lock washer, 3.0-3.1 mm id, 6.2 mm id od |
![]() | 5061-5890 | 🔗O-ring, 1.239 inch id, 2-026, fluorocarbon elastomer, 12/pk |
![]() | 5061-5886 | 🔗O-ring, inner window, 2-021, 12/pk |
![]() | 19256-80010 | 🔗Phosphorus filter, for Agilent 5890 FPD |
![]() | 19256-60510 | 🔗Photomultiplier tube and housing assembly, used with series 6850 and 6890 gas chromatography systems |
![]() | 0515-1084 | 🔗Screw, M3 x 0.5, 12 mm, pan-head |
![]() | 0515-0680 | 🔗Screw, M3 x 0.5, 6 mm, pan-head |
![]() | 1000-1437 | 🔗Sulfur filter for flame photometric detector |
![]() | 19256-80030 | 🔗Window, first |
![]() | 19256-60700 | 🔗Exit tube assembly |
![]() | 19256-20910 | 🔗Filter spacer, use only with sulfur filter for flame photometric detector (p/n 1000-1437) |
![]() | 5188-5953 | 🔗FPD Check Out Sample, Meth. Parathion |
![]() | G1535-00030 | 🔗FPD chimney front, dual wavelength, used with series all 6890 gas chromatography systems |
![]() | 19256-00090 | 🔗FPD clamp, used with series 5890, 6850, 6890, 7820, and 7890 gas chromatography systems |
![]() | G1535-80520 | 🔗FPD cover assembly, used with series 6850, 6890, 7820 and 7890 gas chromatography systems, model 6850B |
![]() | 19256-80600 | 🔗FPD dual wavelength weldment, block assy, used with series 6850, 6890, and 7890 gas chromatography systems |
![]() | 19256-20705 | 🔗FPD exit tube, used with series 5890, 6850 (model 6850B), 6890, and 7890 gas chromatography systems |
![]() | 19256-00200 | 🔗FPD flange ring, used with series 5890, 6850, 6890, 7820, and 7890 gas chromatography systems |
![]() | 19256-20580 | 🔗FPD heat shield, used with series 5890, 6820, 6850, 7820, and 7890 gas chromatography systems |
![]() | G1535-60610 | 🔗FPD heater/sensor assembly, used with series 6890 and 7890 gas chromatography systems |
![]() | G1535-60600 | 🔗FPD ignitor cable, used with series 6850 and 6890 gas chromatography systems |
![]() | 19256-20900 | 🔗FPD lens housing flange assemblyy, used with series 6850, 6890, 7820 and 7890 gas chromatography systems, model 6850B |
![]() | G1535-00010 | 🔗FPD main bracket/support, single, used with series 6850, 6890 (all), 7820, and 7890 gas chromatography systems |
![]() | 19256-20550 | 🔗FPD stainless steel coupling, used with series 5890, 6850, 6890, 7820, and 7890 gas chromatography systems |
![]() | 19256-80560 | 🔗FPD weldment, block, used with series 6850, 6890, and 7890 gas chromatography systems |
![]() | G3436-67000 | 🔗FPD+ preventative maintenance kit, dual |
![]() | 19256-80045 | 🔗Heat-shield gasket, perfluoroelastomer |
![]() | 5188-5245 | 🔗Check-out sample, 3 x 1 mL ampules |
![]() | 19256-20690 | 🔗Collet for glow plug |