G1820-65138 — Nebulizer, concentric, quartz, recommended for organic and high purity analysis

Бренд: Agilent Technologies

Nebulizer, concentric, quartz, recommended for organic and high purity analysis

Specifications

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!— "inside defaultSpecification":{Autosampler Compatibility|MultiLine=I-AS|Other|SPS 3|SPS 4|, Chemical Compatibility|MultiLine=Aqueous|Organic solvents|, Instrument Compatibility|MultiLine=7700|7800|7850|7900|8800|8900|, Material=Quartz, Nebulizer Sample Particle Size Tolerance=40 µm, Notes=Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath., Self Aspirating=Yes, volume not limited, Type=Concentric, UNSPSC Code=41115411}—>

<!—

—>

Autosampler Compatibility

  • <!— "multilineKeyVal pipe value":I-AS

  • Other
  • SPS 3
  • SPS 4
  • —>
    I-AS
  • Other
  • SPS 3
  • SPS 4
Chemical Compatibility

  • <!— "multilineKeyVal pipe value":Aqueous

  • Organic solvents
  • —>
    Aqueous
  • Organic solvents
Instrument Compatibility

  • <!— "multilineKeyVal pipe value":7700

  • 7800
  • 7850
  • 7900
  • 8800
  • 8900
  • —>
    7700
  • 7800
  • 7850
  • 7900
  • 8800
  • 8900
Material
  • Quartz
Nebulizer Sample Particle Size Tolerance
  • 40 µm
Notes
  • Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath.
  • <!— Notes::Recommended for trace analysis of clean samples. Lower contamination level than Pyrex. Clean using 5 % HNO3 (v/v) bath; do not use ultrasonic bath. —>

Self Aspirating
  • Yes, volume not limited
Type
  • Concentric
UNSPSC Code
  • 41115411
Артикул: G1820-65138 Категория: Бренд: