GX96-202IAB — AdvanceBio Gly-X deglycosylation and InstantAB labeling module set, 96-ct

Бренд: Agilent Technologies

AdvanceBio Gly-X deglycosylation and InstantAB labeling module set, 96-ct

Part Number GX96-202IAB
Product Description AdvanceBio Gly-X deglycosylation and InstantAB labeling module set, 96-ct
Count 96
Kit Configuration Sample Prep Module Set
Label InstantAB
Unit 96 Pack

Specifications

<!—

—>

Application

    <!— "multilineKeyVal":

  • Flexible, high-throughput format: process 1 to 96 samples
  • —>

    <!— "multilineKeyVal":

  • Flexible, high-throughput format: process 1 to 96 samples
  • Instant labeling with InstantAB:5-minute N-Glycanase (PNGase F) digestion provides unbiased N-glycan release
  • —>

    <!— "multivalue1":

  • Flexible, high-throughput format: process 1 to 96 samples
  • Instant labeling with InstantAB:5-minute N-Glycanase (PNGase F) digestion provides unbiased N-glycan release
  • —>

    <!— "multivaluekeyval after making as empty":

  • Flexible, high-throughput format: process 1 to 96 samples
  • Instant labeling with InstantAB:5-minute N-Glycanase (PNGase F) digestion provides unbiased N-glycan release
  • —>

  • Flexible, high-throughput format: process 1 to 96 samples
  • Instant labeling with InstantAB:5-minute N-Glycanase (PNGase F) digestion provides unbiased N-glycan release
Count
  • 96
Equipment & Reagents Provided by User

    <!— "multilineKeyVal":

  • 96-well Thermocycler or two independent heat blocks, set for 90°C and 50°C. (e.g. Corning THERM-1001, 110V. THERM-1000, 230V). Note: Two GlykoPrep heaters, GS150, can be fitted with VWR 13259-260 modular heating blocks.
  • —>

    <!— "multilineKeyVal":

  • 96-well Thermocycler or two independent heat blocks, set for 90°C and 50°C. (e.g. Corning THERM-1001, 110V. THERM-1000, 230V). Note: Two GlykoPrep heaters, GS150, can be fitted with VWR 13259-260 modular heating blocks.
  • Vacuum pump (Millipore WP6211560, 110 V, WP6122050, 220V, Welch WOB-L Pump 2522). Note: If you have a vacuum manifold other than the Millipore model suggested, contact us for setup instructions
  • —>

    <!— "multivalue1":

  • 96-well Thermocycler or two independent heat blocks, set for 90°C and 50°C. (e.g. Corning THERM-1001, 110V. THERM-1000, 230V). Note: Two GlykoPrep heaters, GS150, can be fitted with VWR 13259-260 modular heating blocks.
  • Vacuum pump (Millipore WP6211560, 110 V, WP6122050, 220V, Welch WOB-L Pump 2522). Note: If you have a vacuum manifold other than the Millipore model suggested, contact us for setup instructions
  • —>

    <!— "multivaluekeyval after making as empty":

  • 96-well Thermocycler or two independent heat blocks, set for 90°C and 50°C. (e.g. Corning THERM-1001, 110V. THERM-1000, 230V). Note: Two GlykoPrep heaters, GS150, can be fitted with VWR 13259-260 modular heating blocks.
  • Vacuum pump (Millipore WP6211560, 110 V, WP6122050, 220V, Welch WOB-L Pump 2522). Note: If you have a vacuum manifold other than the Millipore model suggested, contact us for setup instructions
  • —>

  • 96-well Thermocycler or two independent heat blocks, set for 90°C and 50°C. (e.g. Corning THERM-1001, 110V. THERM-1000, 230V). Note: Two GlykoPrep heaters, GS150, can be fitted with VWR 13259-260 modular heating blocks.
  • Vacuum pump (Millipore WP6211560, 110 V, WP6122050, 220V, Welch WOB-L Pump 2522). Note: If you have a vacuum manifold other than the Millipore model suggested, contact us for setup instructions
Kit Configuration
  • Sample Prep Module Set
Label
  • InstantAB
Prep time (approx)
  • ~1 hour
Protein Load Range
  • 1-40 µg
Stability
  • Samples may be stored at -20°C for at least 6 months or 4°C for up to 5 days
Technique
  • LC