Agilent o-rings and centering rings for diffusion pumps help create reliable seals with your system. Diffusion pump thermal switches prevent system over-heating conditions and replacement sight glass kits allow replacement of damaged sight glasses or gaskets.
O-Rings, Sight Glass Kits & Thermal Switches for Diffusion Pumps
Бренд: Agilent Technologies
Бренд: Agilent Technologies
Список продуктов
| Фото | Артикул | Описание |
|---|---|---|
![]() | K9050005 - K9050005 — Thermostat, upper switch, set at 200°F (93 °C), for NHS-35 diffusion pump | 🔗 |
![]() | K9050003 - K9050003 — Thermostat, upper switch, set at 220°F (104 °C), for HS-32 diffusion pump | 🔗 |
![]() | L8841301 - L8841301 — Thermoswitch kit for HS-16 and HS-20 diffusion pumps (upper and lower switch, 4’ Ni wire 14 AWG, 6 Ni lugs) | 🔗 |
![]() | L8912301 - L8912301 — Thermoswitch kit for VHS-4, VHS-6, VHS-250, VHS-10, and VHS-400 diffusion pumps. Kit contains: switch, lug, wire and insulator paper. | 🔗 |
![]() | X3900-20003 - X3900-20003 — Thermowell Adapter, ISO G1/2 to M8 | 🔗 |
![]() | 642906041 - 642906041 — Type J Thermocouple | 🔗 |
![]() | K9050002 - K9050002 — Thermostat, lower switch, set at 390°F (199 °C), for HS-16 and HS-20 diffusion pumps | 🔗 |
![]() | K9050004 - K9050004 — Thermostat, lower switch, set at 550 °F (288 °C), for HS-32 diffusion pump | 🔗 |
![]() | L9964002 - L9964002 — Thermostat, set open at 140 °F (60 °C), close at 170 °F (77°C), for AX-65 diffusion pump | 🔗 |
![]() | L9964001 - L9964001 — Thermostat, set open at 365 °F (185 °C), close at 300 °F (149 °C), for AX-65 diffusion pump | 🔗 |
![]() | K9050001 - K9050001 — Thermostat, upper switch, set at 185 °F (85 °C), for HS-16 and HS-20 diffusion pumps | 🔗 |
![]() | L8914001 - L8914001 — Thermal insulator, for VHS-10 and VHS-400 diffusion pumps | 🔗 |
![]() | 642906025 - 642906025 — Thermal switch, set at 300 °F (147 °C), for VHS-4, VHS-6, VHS-250, VHS-10, and VHS-400 diffusion pumps | 🔗 |
![]() | F6253001 - F6253001 — Thermostat bracket, for HS-32 diffusion pump | 🔗 |
![]() | X3900-68006 - X3900-68006 — Thermostat wire, 14 AWG, precut 80 in for HS-16 and HS-20 diffusion pumps | 🔗 |
![]() | X3900-68007 - X3900-68007 — Thermostat wire, 14 AWG, precut 92 in for HS-32 and NHS-35 diffusion pumps | 🔗 |
![]() | K9050006 - K9050006 — Thermostat, lower switch, set at 316 °C, for NHS-35 diffusion pump | 🔗 |
![]() | 642906040 - 642906040 — Resistance thermometer PT100, G1/2 connection, for diffusion pump oil temperature measurement | 🔗 |
![]() | K8475001 - K8475001 — Sight glass for HS-16 diffusion pump | 🔗 |
![]() | F6097301 - F6097301 — Sight glass kit for HS-16, HS-20, HS-32 and NHS-35 diffusion pumps built before Oct ’95 | 🔗 |
![]() | L8908301 - L8908301 — Sight glass kit for VHS-4, VHS-6, VHS-250, VHS-10, VHS-400 diffusion pumps | 🔗 |
![]() | L9227001 - L9227001 — Sight glass metal cover | 🔗 |
![]() | F6252001 - F6252001 — Thermal insulator, center thermostat, for HS-32 diffusion pump | 🔗 |
![]() | K0377183 - K0377183 — O-ring kit, for VHS-4 diffusion pump | 🔗 |
![]() | K0377189 - K0377189 — O-Ring kit, for VHS-400 diffusion pump | 🔗 |
![]() | K0377184 - K0377184 — O-ring kit, for VHS-6 diffusion pump | 🔗 |
![]() | 660892232 - 660892232 — O-ring, for sight glass on HS-16 pump, Viton 2-232 | 🔗 |
![]() | 660892240 - 660892240 — O-ring, for sight glass on HS-20, HS-32 and NHS-35 pumps, FKM 2-240 | 🔗 |
![]() | L9229001 - L9229001 — Oil indicator plate | 🔗 |
![]() | L9223001 - L9223001 — Oil level Borosil sight glass for HS-20, HS-32 and NHS-35 | 🔗 |
![]() | K0377187 - K0377187 — O-ring kit, for M-4 diffusion pump | 🔗 |
![]() | K0377188 - K0377188 — O-ring kit, for M-6 diffusion pump | 🔗 |
![]() | K0377169 - K0377169 — O-ring kit, for NHS-35 diffusion pump. Ensures a reliable seal with your system | 🔗 |
![]() | K0377185 - K0377185 — O-ring kit, for VHS-10 diffusion pump | 🔗 |
![]() | K0377178 - K0377178 — O-ring kit, for VHS-250 diffusion pump | 🔗 |
![]() | K0377164 - K0377164 — O-ring kit, for HS-16 diffusion pump | 🔗 |
![]() | K0377159 - K0377159 — O-ring kit, for HS-2, M-2, and HSA diffusion pumps | 🔗 |
![]() | K0377165 - K0377165 — O-ring kit, for HS-20 diffusion pump | 🔗 |
![]() | K0377167 - K0377167 — O-ring kit, for HS-32 diffusion pump | 🔗 |
![]() | L9165001 - L9165001 — Inlet o-ring, for HS-32 diffusion pump, ISO | 🔗 |
![]() | 78536001 - 78536001 — Inlet o-ring, for NHS-35 diffusion pump, 35 in ASA, Butyl | 🔗 |
![]() | 78536002 - 78536002 — Inlet o-ring, for NHS-35 diffusion pump, ISO 1000F | 🔗 |
![]() | 648056329 - 648056329 — Nickel lug, 14 AWG, for diffusion pump thermostat wires, for HS-16, HS-20, HS-32, and NHS-35 pumps | 🔗 |
![]() | K0377163 - K0377163 — O-ring kit, for HS-10 diffusion pump | 🔗 |
![]() | 660893432 - 660893432 — Foreline o-ring, for HS-20 diffusion pump, 4 in ASA, Butyl | 🔗 |
![]() | 660893443 - 660893443 — Foreline o-ring, for HS-32 diffusion pump, ASA flange | 🔗 |
![]() | 660893267 - 660893267 — Foreline o-ring, for NHS-35 diffusion pump, 6 in ASA, Butyl | 🔗 |
![]() | K8478001 - K8478001 — Graphite sight glass gasket, for HS-16 diffusion pump | 🔗 |
![]() | 48214001 - 48214001 — Inlet o-ring, for HS-16 diffusion pump, 16 in ASA, Butyl | 🔗 |
![]() | 84349002 - 84349002 — Inlet o-ring, for HS-20 diffusion pump, 20 in ASA, Butyl | 🔗 |
![]() | 45390001 - 45390001 — Inlet o-ring, for HS-32 diffusion pump, 32 in ASA, Butyl | 🔗 |
![]() | 660890348 - 660890348 — Foreline o-ring, for HS-16 diffusion pump, 3 in ASA, Buna | 🔗 |