Easy, Accurate Water Analysis of 22 Sample Types/39 Items
Measurement
Combining the UV-1280 and a simple reagent kit from Kyoritsu Chemical-Check Lab ensures easy operation, and accurate, stable water analysis.
| Item name | Reagent type / cell Other necessary instruments | Measurement principle Measurement range(mg/L) / measurement time | |
|---|---|---|---|
| ClO | Residual Chlorine(Free) |
Specific cup*2 |
DPD Absorptiometry
|
| CN | Free Cyanide |
Specific cup*1 |
4-Pyridinecarboxylic Acid Absorptiometry
|
| CNT | Total Cyanide |
Water Analysis Set: Total Cyanide |
Distillation and Picric Acid Absorptiometry
|
| COD | COD |
|
Oxidation by potassium permanganate in alkaline medium Method
|
| Color | Chromaticity |
|
Verification by Platinum Cobalt Color standard solution
|
| Cr6+ | Hexavalent Chromium |
|
Diphenylcarbazide Absorptiometry
|
| Cr6+-50 | Hexavalent Chromium-50mm cell |
Sample chamber unit, square length absorbing cell holder |
Diphenylcarbazide Absorptiometry
|
| Cr6+(D) | Hexavalent Chromium (Low Range) |
Specific cup *1 |
Diphenylcarbazide Absorptiometry Coupled with Collecting on Membrane Filter
|
| Cr6+(WAK) | Hexavalent Chromium (PACKTEST) |
Specific cup *2 |
Diphenylcarbazide Absorptiometry
|
| CrT | Total Chromium*4 |
Heating equipment |
Oxidation and Diphenylcarbazide Absorptiometry
|
| Cu | Copper |
Specific cup *2 |
Bathocuproine Absorptiometry
|
| F | Fluorine (Free) |
Specific cup *2 |
Lanthanum — Alizarin Complexon Absorptiometry
|
| Fe | Iron |
Specific cup *2 |
Reduction and o-Phenanthroline Absorptiometry
|
| Fe (D) | Iron (Low Range) |
Specific cup *2 |
Reduction and Bathophenanthroline Absorptiometry
|
| FOR | Formaldehyde |
Specific cup *1 |
MBTH Absorptiometry
|
| H2O2 | Hydrogen Peroxide |
Specific cup *2 |
4-Aminoantipyline Absorptiometry with Enzyme
|
| Mn | Manganese |
Specific cup *2 |
Potassium Periodate Absorptiometry
|
| NH4 | Ammonium |
Specific cup *2 |
Indophenol Blue Absorptiometry
|
| NH4-N | Ammonium Nitrogen |
Specific cup *2 |
Indophenol Blue Absorptiometry
|
| Ni | Nickel |
Specific cup *2 |
Nioxime Absorptiometry
|
| NO2 | Nitrite*4 |
|
Naphthylethylenediamine Absorptiometry
|
| NO2-N | Nitrite Nitrogen*4 |
|
Naphthylethylenediamine Absorptiometry
|
| NO3 (1) | Nitrate (No Nitrite)*4 |
Stirring vessel with a lid |
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3 (2) | Nitrate (Nitrite 0.015mg / L or less)*4 |
Stirring vessel with a lid, LR-NO2 |
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3 (3) | Nitrate (Nitrite 5mg / L or less)*4 |
Stirring vessel with a lid, heating equipment, NO3-RA |
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3-N (1) | Nitrate Nitrogen (No Nitrite Nitrogen)*4 |
Stirring vessel with a lid |
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3-N (2) | Nitrate Nitrogen (Nitrite Nitrogen 0.015mg / L or less)*4 |
Stirring vessel with a lid, LR-NO2 |
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3-N (3) | Nitrate Nitrogen (Nitrite Nitrogen 1.5mg / L or less)*4 |
Stirring vessel with a lid, heating equipment, NO3-RA |
Reduction and Naphthylethylenediamine Absorptiometry
|
| Pb | Lead |
Specific cup *1 |
MetaSEP Analig® and PAR Absorptiometry
|
| Phenol | Phenol*4 |
Specific cup *1 |
4-Aminoantipyline Absorptiometry with Enzyme
|
| PO4 | Phosphate*4 |
Specific cup *1 |
Molybdenum Blue Absorptiometry
|
| PO4(D) | Phosphate (Enzymatic method) |
Specific cup *2 |
4-Aminoantipyline Absorptiometry with Enzyme
|
| PO4-P | Phosphate Phosphorus*4 |
Specific cup *1 |
Molybdenum Blue Absorptiometry
|
| PO4-P(D) | Phosphate Phosphorus (Enzymatic method) |
Specific cup *2 |
4-Aminoantipyline Absorptiometry with Enzyme
|
| S | Sulfide (Hydrogen Sulfide) |
Specific cup *1 |
Methylene Blue Absorptiometry
|
| TH | Total Hardness |
Specific cup *2 |
Phthalein Complexone Absorptiometry
|
| Turbid (FTU) | Turbidity(Formazin) |
|
Verification by Formazin standard solution
|
| Turbid (PS) | Turbidity(Polystyrene) |
|
Verification by Polystyrene standard solution
|
| Zn (D) | Zinc(Low Range) |
Specific cup *1 |
5-Br-PAPS Absorptiometry
|
*1 One dedicated cup is included in the reagent kit. *2 Please use the dedicated cup (WAK-CC 10 Pack Test Cup, 10 pieces) manufactured by Kyoritsu Chemical Research Institute. *3 Approximate total time including pre-processing. *4 The reagent has been discontinued.
* If the program version of your UV-1280 is 1.xx, your program must be updated by a Shimadzu service engineer. The program version is displayed on the bottom right of the Initialization screen.