Specifications
Specifications depend on the configuration and installed modules. Performance limits are stated for the conditions specified by the manufacturer. Modules and options are selected to suit the method and are not included by default.
| Manufacturer | Thermo Fisher Scientific Inc. |
|---|---|
| Part number | To be confirmed |
| Platform | TRACE 1610 GC; configuration tailored to the application and method |
| Analytical channels | Up to four in the appropriate configuration |
| Main oven | From ambient temperature +3 °C to 450 °C; optional cryogenic cooling |
| Main oven heating | Up to 125 °C/min with the appropriate electrical configuration and temperature range |
| Auxiliary oven | TRACE 1600 Auxiliary Oven: isothermal operation up to 300 °C |
| Valve capacity | The auxiliary oven accommodates up to eight diaphragm valves or up to six rotary valves |
| Additional detectors | Two iConnect slots in the Auxiliary Oven; data acquisition for these channels at up to 10 Hz |
| Secondary oven | Optional, up to 250 °C; installed as an alternative to the methanizer |
| Methanizer | Optional nickel reactor rated up to 400 °C for determining CO and CO₂ with an FID |
| Sample introduction | Gas and liquid sampling valves, or inlets and autosamplers |
| Control | Chromeleon CDS, with application-specific calculations and reports |
| Dimensions and weight | Depend on the auxiliary oven, valves, detectors and sampling equipment |
Platform and module limits do not replace the specifications of the selected analyzer. The listed standards apply to the corresponding configurations. Confirm whether the particular edition of the method applies when selecting the system.
Description
TRACE 1610 analyzers are supplied with combinations of valves, columns and detectors selected for specific gas analysis methods. Available workflows include natural gas, refinery gas, permanent gases and trace impurities.
Detector and channel counts depend on the analyzer configuration. The 1610 greenhouse-gas configuration is a separate ordering option.
Documentation and sources
Details and configurations in the source catalogue.
Specification source ↗NABITEX SCIENTIFIC
Supply and support
Service
Our service engineers are certified specialists ready to address a range of technical challenges. We provide equipment support throughout its service life.
What we offer:
- Commissioning: installation, commissioning and diagnostics.
- Validation and compliance: installation qualification (IQ), operational qualification (OQ) and performance qualification (PQ) in accordance with good manufacturing practice (GMP).
- Accuracy control: metrological verification of equipment.
- Repair and maintenance: scheduled maintenance and responsive after-sales service.
- IT support: software setup and adaptation.
Training and methods:
Our engineers train staff to operate the equipment and develop and implement measurement methods for specific customer needs.
Selection
Equipment selected for your requirements
Our team includes specialists from different industries and certified service engineers. We provide technical advice and select equipment, spare parts and consumables with an understanding of your production requirements.
What we offer:
- Turnkey configuration: a complete equipment package for your process.
- Standards and requirements: work in accordance with GOST standards, technical specifications and user requirements specifications (URS).
- Compatibility assurance: we consider the details needed for equipment, accessories and materials to work as a system.
Payment
We work exclusively with legal entities and offer tailored arrangements for financing purchases.
Available payment arrangements:
100% payment after delivery: payment deferred by 5 to 90 calendar days.
Partial advance payment plus payment after delivery:
- 70% / 30%
- 50% / 50%
- 30% / 70%
- Instalments: payment can be split into several parts if required.
Special warehouse offer
Collect the goods now and pay later. We undertake to store your order for 6 to 24 months.
You receive 100% deferred payment for the entire period.
Contact our managers for details.
Delivery
We deliver orders throughout Russia and CIS countries. We handle both standard shipments and temperature-sensitive goods (at +2 to +8°C and −20°C).
Delivery and collection options:
Delivery to your door
- Moscow and Moscow region: prompt delivery using our own vehicles.
- Other Russian regions and CIS countries: shipment through a carrier of your choice.
Collection from our Moscow warehouse
- Additional services: on request, we perform rigging work, including loading, unloading and moving heavy equipment.
Warranty
All equipment we supply carries a 12 to 36 month warranty, depending on the manufacturer.
Our supplier relationships help us promptly provide warranty spare parts for repair or replacement equipment in the event of a defect.
Thermo Scientific TRACE 1610 GC Analyzers from the representative of Thermo Fisher Scientific Inc.
For the current price of “Thermo Scientific TRACE 1610 GC Analyzers”, and a quotation, please send an enquiry using the form below.
- Individual attention to enquiries
- Fast delivery directly to your warehouse
- Equipment upgrades and service
- Direct contacts with leading suppliers